Department of Otolaryngology-Head and Neck Surgery, Kosin University Gospel Hospital, Kosin University College of Medicine, Busan, Korea
© 2026 Kosin University College of Medicine.
This is an open-access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (https://creativecommons.org/licenses/by-nc/4.0/) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited.
Conflicts of interest
No potential conflict of interest relevant to this article was reported.
Funding
None.
Author contributions
All the work was done by Yeongjoon Kim.
| Modality | Description | Strengths | Limitations and suitability for H&N FNA |
|---|---|---|---|
| Static-image transmission | Selected microscopic fields are captured as still images at the procedure site and transmitted to a remote reviewer | Simple implementation, low equipment cost, and ease of deployment across sites with limited infrastructure | Highly vulnerable to field-selection bias because the remote reviewer evaluates only the fields selected on site; this is particularly limiting in heterogeneous H&N specimens, such as necrotic cervical lymph nodes and focal salivary gland lesions |
| Dynamic real-time telecytology (live video) | Live video microscopy with two-way interaction between the on-site operator and the remote cytopathologist; the reviewer can request additional fields, focus adjustment, and changes in magnification | Provides real-time adequacy feedback, supports immediate decisions about additional passes and ancillary triage, and is well suited to telecytology-assisted ROSE | Diagnostic value still depends on operator skill in slide navigation and stable image transmission; performance can decline with limited bandwidth or inexperienced operators. Nevertheless, this modality is a practical initial platform for many H&N FNA workflows, particularly when rapid adequacy feedback is required |
| Robotic microscopy | A motorized microscope stage allows the remote reviewer to directly control field selection and focus without assistance from on-site cytology personnel manipulating the slide | Provides greater reviewer autonomy than operator-driven live video systems and reduces dependence on on-site field-selection skill | Higher equipment and integration costs; requires dedicated infrastructure and IT support; less practical as an entry-level platform for resource-constrained H&N services |
| Whole-slide imaging | The entire glass slide is digitized at high resolution; the remote reviewer evaluates the digital slide using dedicated viewer software, often with multifocal image acquisition, such as Z-stacking | Supports asynchronous review, archiving, standardization, second-opinion consultation, and integration with computational and AI tools | Cytology specimens span multiple focal planes, often requiring Z-stacking or extended-focus imaging, which increases scan time, file size, and review burden; routine integration into procedure-linked H&N ROSE workflows is still evolving |
| Lesion category | Evidence strength for telecytology | Reporting framework | Primary value of telecytology | Key considerations and limitations |
|---|---|---|---|---|
| Thyroid lesions | Strongest among H&N applications | The Bethesda System for Reporting Thyroid Cytopathology, third edition | Supports adequacy assessment during ultrasound-guided FNA; has been reported to reduce unsatisfactory rates in selected thyroid FNA workflows; guides preliminary triage for additional passes, cell block preparation, and molecular testing; and provides the most mature model among H&N applications | Sparsely cellular, hemorrhagic, and cystic aspirates remain susceptible to misclassification; WSI evidence is supportive but not yet definitive for routine real-time replacement of conventional procedure-linked review |
| Cervical lymph nodes and metastatic neck masses | Moderate; supported by focused dynamic telecytology studies of H&N non-thyroid lesions | No single dominant cytopathology framework; the Sydney System for Reporting Lymph Node FNAC has been proposed | Provides real-time procedural support during ultrasound-guided aspiration; is particularly valuable for necrotic or cystic neck masses; and can trigger ancillary triage, including flow cytometry, cell block preparation, and microbiologic studies, when lymphoma or atypical metastasis is suspected | A broad differential diagnosis, including reactive, infectious, granulomatous, metastatic, and lymphomatous processes, limits the diagnostic conclusiveness of cytology alone; definitive lymphoma classification still requires adequate tissue procurement and a full ancillary workup |
| Salivary gland lesions | Limited; not specifically validated in dedicated telecytology studies | The Milan System for Reporting Salivary Gland Cytopathology, second edition | Supports adequacy assessment, repeat-sampling decisions, and preservation of material for ancillary testing in distributed outpatient and image-guided settings; also facilitates communication between the proceduralist and the reviewing pathologist | Cytomorphologic overlap, matrix-rich backgrounds, heterogeneous cellularity, and focal diagnostic components increase susceptibility to field-selection bias; this modality is best framed as an adjunct to, rather than a substitute for, conventional cytopathology review |
| Domain | Key challenges | Mitigation strategies and implementation considerations |
|---|---|---|
| Image and specimen quality | Adequate resolution, color fidelity, illumination, and focus are required to preserve cytomorphologic detail; cytology specimens span multiple focal planes, which complicates static-image and WSI-based review, and Z-stacking increases scan time and file size | Use validated image-acquisition equipment, calibrated displays, and standardized staining protocols. For WSI cytology, adopt Z-stacking or extended-focus imaging when feasible. Perform institution-specific validation before clinical deployment |
| Operator and reviewer dependence | Diagnostic value depends on the on-site operator’s skill in slide navigation, focus adjustment, and field selection, as well as on the remote reviewer’s familiarity with digital cytology. This is particularly relevant for heterogeneous H&N aspirates, including cystic, necrotic, hemorrhagic, and hypocellular specimens | Provide structured training and competency assessment for both on-site and remote personnel. Consider trained clinical imaging assistants for ROSE coverage when cytology personnel are unavailable. Conduct periodic concordance audits |
| Validation and quality assurance | Telecytology platforms must be validated against conventional microscopy for the intended clinical use; performance may vary by platform, personnel, specimen type, and workflow | Apply society-level validation recommendations. Document hardware, software, personnel competency, and workflow. Monitor concordance, adequacy, turnaround time, and technical failure rates |
| Workflow integration and communication | Telecytology performance depends on coordinated specimen preparation, image acquisition, remote review, and bidirectional communication during procedures; ad hoc implementation increases the risk of nondiagnostic outcomes | Define standard operating procedures specifying who prepares the smear, who navigates the slide, how adequacy feedback is communicated, and how requests for additional passes and ancillary testing are transmitted. Integrate telecytology with the LIS and procedure-room workflow |
| Regulatory and data governance | Cross-institutional transmission of cytologic images and clinical information must comply with applicable data protection regulations; medicolegal responsibilities for remote diagnoses are not uniformly defined across jurisdictions | Implement secure image transmission, access controls, audit trails, and institution-level governance. In Korea, ensure compliance with the Personal Information Protection Act. Use institutional and inter-institutional agreements to clarify reviewer responsibilities and reporting authority |
| Reimbursement and economic sustainability | Dedicated reimbursement pathways for telecytology and telecytology-based ROSE remain limited or absent in many systems, including the Korean National Health Insurance framework; capital costs and ongoing maintenance can constrain adoption beyond pilot programs | Begin with low-overhead dynamic video platforms within single institutions or governed networks. Evaluate reimbursement feasibility and institutional cost-sharing models. Share infrastructure across affiliated centers. Build on existing Korean digital pathology and digital cytopathology QA experience |
H&N, head and neck; FNA, fine-needle aspiration; ROSE, rapid on-site evaluation; IT, information technology; AI, artificial intelligence.
H&N, head and neck; FNA, fine-needle aspiration; WSI, whole-slide imaging; FNAC, fine-needle aspiration cytology.
WSI, whole-slide imaging; H&N, head and neck; ROSE, rapid on-site evaluation; LIS, laboratory information system; QA, quality assurance.