We report a case of difficult endotracheal intubation in a patient with tracheobronchopathia osteochondroplastica. A 65-year-old man was scheduled to undergo ulnar nerve decompression and ganglion excisional biopsy under general anesthesia. During induction of general anesthesia, an endotracheal tube could not be advanced through the vocal cords due to resistance. A large number of nodules were identified below the vocal cords using a GlidescopeĀ® video-laryngoscopy, and fiberoptic bronchoscopy revealed irregular nodules on the surface of the entire trachea and the main bronchus below the vocal cords. Use of a small endotracheal tube was attempted and failed. a laryngeal mask airway (LMA Supreme ā„¢) rather than further intubation was successfully used to maintain the airway.